Skip to content

Huawei Cloud DCAAS Cloud Direct Connect

Collect Huawei Cloud DCAAS Metrics data

Configuration

Install Func

It is recommended to enable Guance Integration - Extensions - DataFlux Func (Automata): All prerequisites are automatically installed, please continue with the script installation.

If you deploy Func on your own, refer to Self-deployed Func

It is recommended to deploy the GSE version.

Install Script

Note: Please prepare a Huawei Cloud AK that meets the requirements in advance (for simplicity, you can directly grant global read-only permission ReadOnlyAccess).

To synchronize Huawei Cloud DCAAS monitoring data, we install the corresponding collection script:

  • guance_huaweicloud_dcaas_virtual_interfaces: Collects DC cloud direct connect virtual interface monitoring Metrics data.
  • guance_huaweicloud_dcaas_direct_connects: Collects DC cloud direct connect physical connection monitoring Metrics data.

After clicking 【Install】, enter the corresponding parameters: Huawei Cloud AK and Huawei Cloud account name.

Click 【Deploy Startup Script】, and the system will automatically create a Startup script set and automatically configure the corresponding startup script.

After the script is installed, find the script "Guance Integration (Huawei Cloud - Cloud Direct Connect DC - Virtual Interface)" / "Guance Integration (Huawei Cloud - Cloud Direct Connect DC - Physical Connection)" under "Development" in Func, unfold and modify this script. Find collector_configs and monitor_configs, respectively edit the content of region_projects, change the region and Project ID to the actual region and Project ID, then click Save and Publish.

In addition, you can see the corresponding automatic trigger configuration under "Manage / Automatic Trigger Configuration". Click 【Execute】 to immediately execute it once without waiting for the scheduled time. Wait a moment, and you can view the execution task records and corresponding logs.

Verification

  1. In "Manage / Automatic Trigger Configuration", confirm whether the corresponding automatic trigger configuration exists for the task, and you can also check the corresponding task records and logs for any anomalies.
  2. On the Guance platform, in "Infrastructure - Resource Catalog", check if there is any asset information.
  3. On the Guance platform, in "Metrics", check if there is any corresponding monitoring data.

Metrics

You can collect more Metrics from Huawei Cloud DCAAS by configuring them Huawei Cloud DCAAS Metrics Details

Metric ID Metric Name Metric Meaning Value Range Measurement Object Monitoring Period (Original Metric)
network_incoming_bits_rate Network Incoming Bandwidth Bitrate of incoming data at the cloud direct connect side. Unit: bit/s ≥ 0 bit/s Physical connection and historical physical connections 1 minute
network_outgoing_bits_rate Network Outgoing Bandwidth Bitrate of outgoing data at the cloud direct connect side. Unit: bit/s ≥ 0 bit/s Physical connection and historical physical connections 1 minute
network_incoming_bytes Network Incoming Traffic Number of bytes of incoming data at the cloud direct connect side. Unit: byte ≥ 0 bytes Physical connection and historical physical connections 1 minute
network_outgoing_bytes Network Outgoing Traffic Number of bytes of outgoing data at the cloud direct connect side. Unit: byte ≥ 0 bytes Physical connection and historical physical connections 1 minute
network_incoming_packets_rate Network Incoming Packet Rate Packet rate of incoming data at the cloud direct connect side. Unit: Packet/s ≥ 0 packets/s Physical connection and historical physical connections 1 minute
network_outgoing_packets_rate Network Outgoing Packet Rate Packet rate of outgoing data at the cloud direct connect side. Unit: Packet/s ≥ 0 packets/s Physical connection and historical physical connections 1 minute
network_incoming_packets Network Incoming Packets Number of incoming data packets at the cloud direct connect side. Unit: Packet ≥ 0 packets Physical connection and historical physical connections 1 minute
network_outgoing_packets Network Outgoing Packets Number of outgoing data packets at the cloud direct connect side. Unit: Packet ≥ 0 packets Physical connection and historical physical connections 1 minute
network_status Port Status Port status of the cloud direct connect physical connection. 0-DOWN 1-UP Physical connection and historical physical connections 1 minute
bgp_receive_route_num_v4 Received IPV4 Route Entries Number of IPV4 route entries learned by the virtual interface through BGP protocol. ≥0 entries Virtual interfaces 1 minute
bgp_receive_route_num_v6 Received IPV6 Route Entries Number of IPV6 route entries learned by the virtual interface through BGP protocol. ≥0 entries Virtual interfaces 1 minute
bgp_peer_status_v4 IPv4 BGP PEER Status IPv4 BGP PEER status 0-DOWN 1-ACTIVE Virtual interfaces 1 minute
bgp_peer_status_v6 IPv6 BGP PEER Status IPv6 BGP PEER status 0-DOWN 1-ACTIVE Virtual interfaces 1 minute
in_errors Network Incoming Error Packets Number of incoming error packets at the cloud direct connect side. 0-2^23 Virtual interfaces 1 minute

Objects

After data synchronization is normal, you can view the data in "Infrastructure - Resource Catalog" on the Guance platform.

  • DC cloud direct connect virtual interface object data:
{
  "measurement": "huaweicloud_dcass_virtual_interface",
  "tags": {
    "RegionId"                : "cn-south-1",
    "project_id"              : "756ada1aa17exxxxb2a16ea41912e52d",
    "enterprise_project_id"   : "320a1900-b6d2-xxxx-a348-0979986b730b",
    "tenant_id"               : "07d662153ada40c5bd984601976xxxx",
    "virtual_interface_id"    : "ccaad430-389c-4fe6-xxxx-2543e1b0d1b5",
    "virtual_interface_name"  : "vif-xxxx-xx-2g02",
    "direct_connect_id"       : "b032de49-2932-4ae3-xxxx-c0234f60afce",
    "status"                  : "ACTIVE"
  },
  "fields": {
    "type"              : "private",
    "service_type"      : "GDGW",
    "vgw_id"            : "xxxxxxxxxx",
    "bandwidth"         : "500",
    "description"       : "{JSON Data}",
    "device_id"         : "120.87.xxx.9",
    "create_time"       : "2024/11/21 18:31:22",
    "tags"              : "[]"
  }
}

Note: Fields in tags and fields may change with subsequent updates.

Tip 1: The value of virtual_interface_id is the DC virtual interface ID, used as unique identification.

Tip 2: ACTIVE,DOWN are the values corresponding to status.

  • DC cloud direct connect physical connection object data:
{
  "measurement": "huaweicloud_dcass_virtual_interface",
  "tags": {
    "RegionId"                : "cn-south-1",
    "project_id"              : "756ada1aa17exxxxb2a16ea41912e52d",
    "enterprise_project_id"   : "320a1900-b6d2-xxxx-a348-0979986b730b",
    "tenant_id"               : "07d662153ada40c5bd984601976xxxx",
    "direct_connect_id"       : "ccaad430-389c-4fe6-xxxx-2543e1b0d1b5",
    "direct_connect_name"     : "vif-xxxx-xx-2g02",
    "status"                  : "ACTIVE"
  },
  "fields": {
    "type"              : "private",
    "bandwidth"         : "500",
    "description"       : "{JSON Data}",
    "location"          : "Shanghaixx-xxx",
    "provider"          : "others",
    "provider_status"   : "ACTIVE",
    "charge_mode"       : "prepayment",
    "device_id"         : "xx.87.xxx.9",
    "hosting_id"        : "345ed71f-91b6-4248-xxxx-952bdb1c3706",
    "port_type"         : "40G",
    "apply_time"        : "2023-05-24T08:53:05.000Z",
    "create_time"       : "2024/11/21 18:31:22",
    "tags"              : "[]"
  }
}

Note: Fields in tags and fields may change with subsequent updates.

Tip 1: The value of direct_connect_id is the physical connection ID, used as unique identification.

Tip 2: ACTIVE,DOWN are the values corresponding to status.

Feedback